"You've got a little work to do."
We don't claim to be electricians or electrical engineers. So when I called the inspector to see if he'd been by, it was no surprise when he said "You've got a little work to do." Doh! 1. Remove the ground screw-wrong application. 2. Isolate ground and neutral in load center 3. Move ground rods to one side of meter box 4. Ground rods require one continuous wire-not a separate one to each and last 5. Wrong clamps connecting ground rod to ground wire. So with those corrected, although I'm still not sure we have the right clamps, we will try try again tomorrow. Here's the fixed versions.
Note: The copper wire coming from the top actually must be hooked directly to the ground bar on the left side of the panel rather than grounded to the box.

Note: The copper wire coming from the top actually must be hooked directly to the ground bar on the left side of the panel rather than grounded to the box.